--- title: "X7 RS485 port" slug: "x7-rs485-port" updated: 2024-07-04T11:00:20Z published: 2024-07-04T11:00:20Z canonical: "docs-linescan.alliedvision.com/x7-rs485-port" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs-linescan.alliedvision.com/llms.txt > Use this file to discover all available pages before exploring further. # X7 RS485 port The following connector is required: - Würth Elektronik 691 325 110 005 The following counterpart is required: - Würth Elektronik 691 364 100 005 | pin | name | description | | --- | --- | --- | | 1 | RT1 | RS485 | | 2 | RTN1 | RS485 | | 3 | RT2 | RS485 (internally connected to RT1) | | 4 | RTN2 | RS485 (internally connected to RTN1) | | 5 | GND | | Use this interface to connect several XLC4 control units to a single bus line. The XLC4 control unit uses 2 wire RS485 operation. > [!NOTE] > NOTE > > The XLC4 control unit has no integrated bus termination resistors for the control unit at the end of the line. > > Connect a resistor of 120 Ω to RT2 and RTN2. > > For more information refer to [RS485 Bus configuration](/v1/docs/rs485-bus-configuration)