--- title: "User Set Control" slug: "user-set-control-2-1-1" updated: 2025-01-07T16:37:55Z published: 2025-01-07T16:39:30Z canonical: "docs-linescan.alliedvision.com/user-set-control-2-1-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs-linescan.alliedvision.com/llms.txt > Use this file to discover all available pages before exploring further. # User Set Control ## Loaded User Set | Name | LoadedUserSet | **Custom** | | --- | --- | --- | | Description | Specifies the last loaded user set. | | Interface | String | | String length | 32 | | Access mode | Read Only | | Adjustable while grabbing | Yes | | Value range | - | | Default value | **Default** | | Availability | ALL | | Notes | **-** | | Error behavior | See the device error code documentation. | ## User Set Selector | Name | UserSetSelector | **Standard** | | --- | --- | --- | | Description | Selects the feature User Set to load, save or configure. | | Interface | Enumeration | | Access mode | Read/Write | | Adjustable while grabbing | Yes | | Value range | See enum entries table below. | | Default value | **UserSet1** | | Availability | ALL | | Notes | - | | Error behavior | See the device error code documentation. | User Set Selector Enum Entries: | Name | Description | | --- | --- | | UserSet1 | Selects the UserSet 1 | | UserSet2 | Selects the UserSet 2 | | UserSet3 | Selects the UserSet 3 | | UserSet4 | Selects the UserSet 4 | | UserSet5 | Selects the UserSet 5 | | UserSet6 | Selects the UserSet 6 | | UserSet7 | Selects the UserSet 7 | | UserSet8 | Selects the UserSet 8 | | Default | Selects the Default | ### User Set Load | Name | UserSetLoad[UserSetSelector] | **Standard** | | --- | --- | --- | | Description | Loads the User Set specified by **UserSetSelector** to the device and activates it. | | Interface | Command | | Access mode | Read/Write | | Adjustable while grabbing | No | | Value range | 1 | | Default value | 1 | | Availability | ALL | | Notes | - | | Error behavior | See the device error code documentation. | ### User Set Save | Name | UserSetSave[UserSetSelector] | **Standard** | | --- | --- | --- | | Description | Save the current user settings to the selected user set in the non-volatile memory of the device. | | Interface | Command | | Access mode | Read/Write | | Adjustable while grabbing | Yes | | Value range | 1 | | Default value | 1 | | Availability | ALL | | Notes | **Default** is Read only. | | Error behavior | See the device error code documentation. | ### User Set Comment | Name | UserSetComment[UserSetSelector] | **Custom** | | --- | --- | --- | | Description | Leave a comment here to describe the chosen setting. | | Interface | String | | String length | 32 | | Access mode | Read/Write | | Adjustable while grabbing | Yes | | Value range | - | | Default value | **Default** | | Availability | ALL | | Notes | **Default** user set is Read only. When executing User Set Save the comment of the active user set is stored to flash. | | Error behavior | See the device error code documentation. | Feature available for allPIXA evo and allPIXA neo